Intente buscar por palabras clave, código de producto/pedido o número de serie, por ejemplo, "CM442" o "información técnica"
Introduzca por lo menos 2 caracteres para iniciar la búsqueda.
  • Historial
product picture of the ultrasonic flowmeter FLOWSIC500

FLOWSIC500
ultrasonic flowmeter

Custody transfer measurement in natural gas distribution

IFL500
Please Wait (spinning wheel)
Cargando precio
Precios no disponibles temporalmente
Price on request
Activando precio
precio: proporcionar información
Filtrar tarea de medición/aplicación
Tarea de medición / aplicación

Configurar para descargar los dibujos CAD de este producto

  • Principio de medida

    Ultrasonic transit time difference measurement

  • Measured variables

    Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
    (*) additional function included with integrated volume correction

  • Measuring Medium

    Natural gas (dry, odorized)

  • Repeatability

    ≤ 0.1 %

  • Accuracy

    Qmin up to 0.1 Qmax ≤ ± 1 %
     
    0.1 Qmax up to Qmax ≤ ± 0.5 %
    Accuracy class 1; maximum allowed error limits
     
    Qmin up to 0.1 Qmax ≤ ± 2 %
     
    0.1 Qmax up to Qmax ≤ ± 1 %
    After high pressure flow calibration: ±0.2 % at test pressure; otherwise ±0.5 %

  • Medium temperature range

    -25 °C ... +60 °C
    Optional: –40 °C ... +70 °C
     
    (–13 °F ... +140 °F
    Optional: –40 °F ... +158 °F)

  • Operating pressure range

    PN16 (EN 1092-1): 0 bar (g) ... 16 bar (g) / 0 psi(g) ... 232 psi(g)
     
    Class 150 (ASME B16.5): 0 bar (g) ... 20 bar (g) / 0 psi(g) ... 290 psi(g)

  • Nominal pipe size

    DN 50 (2") … DN 150 (6")

  • Metrological approvals and certificates

    MID: 2014/32/EU
    OIML R 137-1&2:2012
    EN 12405: 2010 (for integrated flow conversion)

  • Hazardous area approvals

    IECEx
    Ex ia [ia] IIC T4 Gb, Ex op is IIC T4 Gb
     
    ATEX
    II 2G Ex ia [ia] IIC T4 Gb, II 2G Ex op is IIC T4 Gb
     
    NEC/CEC (US/CA)
    CSA: I.S. for Class 1 Division 1 Groups C and D T4; Ex/AEx ia IIB T4 Ga

  • Digital Outputs

    Configurations:
    LF pulses + malfunction, electrically isolated (fmax = 100 Hz)
     
    HF pulses + malfunction, electrically isolated (fmax = 2 kHz)
     
    Encoder + LF pulses, electrically isolated (fmax = 100 Hz)
     
    Encoder + HF pulses, not electrically isolated (fmax = 2 kHz)
     
    2x pulses, HF and LF, electrically isolated (fmax = 2 kHz / 100 Hz)

  • Digital communication

    R-S485 (external powered, in combination with LF- or HF pulses)